Hempatherm IC 175 is a waterbased thermal insulation coating. Based on aerogel technology and a special acrylic resin blend, the product offers best-in-class thermal insulation properties suitable for a wide range of applications. Hempatherm IC 175 cures to a hydrophobic layer that is able to resist water retention and thereby maintains reliable and consistent thermal insulation performance over its service life. The coating forms a seamless and flexible layer that is able to withstand thermal cycling and prevents corrosion under insulation (CUI).
Hempatherm IC 175 can be used in new construction and maintenance on external surfaces of process pipework, valves, pressure vessels, storage tanks, and other equipment to provide thermal insulation for energy retention and condensation control. It can be used as an alternative to conventional thermal insulation and jacketing in both heated and cold service.
100°C [212°F]
Legislation | Value |
---|---|
EU | 0 g/L [0.00 lb/US gal] |
US (coatings) | 0 g/L [0.00 lb/US gal] |
US (regulatory) | 0 g/L [0.00 lb/US gal] |
China | 0 g/L [0.00 lb/US gal] |
According to specific legislation, see details in the Explanatory Notes available at Hempel website, hempel.com or at your local Hempel website. VOC values may vary with shade, please consult the Safety Data Sheet, section 9.
Handle with care. Before and during use, observe safety labels on packaging and paint containers and follow all local and national safety regulations. Always consult Hempel’s Safety Data Sheet for this product along with the Product Data Sheet.
For professional use only.
Consult Hempel’s separate Surface Preparation Guidelines for more details.
Base 58488 : Insulation powder 99484 (88 : 12 by weight)
Stir well before use. Thinning is not allowed.
Not recommended
Fresh water
Tool | Thinning max vol. | Application parameters |
---|---|---|
Air spray | Not recommended | Nozzle orifice: 0.24″ |
Spray data are indicative and subject to adjustment. Pressure is for a material temperature of 20°C [68°F].
Low | High | Recommended | |
---|---|---|---|
Dry film thickness | 1000 micron [40 mils] | 5000 micron [200 mils] | 2000 micron [80 mils] |
Wet film thickness | 1064 micron [43 mils] | 5319 micron [213 mils] | 2128 micron [85 mils] |
Theoretical spreading rate | 0.9 m²/L [37 sq ft/US gal] | 0.2 m²/L [8 sq ft/US gal] | 0.5 m²/L [20 sq ft/US gal] |
Surface temperature | Touch dry min | Hard dry min | Dry to handle hours | Fully cured hours |
---|---|---|---|---|
20°C [68°F] | 30 min | 120 min | 3 h | 24 h |
Quality name | 10°C [50°F] | 20°C [68°F] | 30°C [86°F] | 40°C [104°F] |
---|---|---|---|---|
Hempatherm IC 175 Min | 3 h | 2 h | 90 min | 60 min |
Hempatherm IC 175 Max | Ext* | Ext* | Ext* | Ext* |
Hempatherm IC 170 Min | 24 h | 18 h | 16 h | 12 h |
Hempatherm IC 170 Max | Ext* | Ext* | Ext* | Ext* |
Ext*: Depending on the actual exposure conditions, the coated surface is overcoatable for an extended period of time. Contact your local Hempel representative for advice.
Ambient temperature | Base | Insulation powder |
---|---|---|
25°C [77°F] | 24 months | 24 months |
Shelf life from date of production, when stored in original unopened containers. Thereafter, the product quality must be re-inspected. Storage at elevated temperatures may reduce shelf life. For advice, please consult Hempel.
Dry film thickness | GWP (Global Warming Potential) |
---|---|
1 µm | 1.1 g CO₂e/m² |
1 mil | 0.006 lb CO₂e/ft² |
The carbon footprint is for 1 square meter / square foot of surface area with a dry film thickness of 1 micron / mil.
The scope includes raw materials, in-bound transport to the Hempel factory, Hempel manufacturing processes, and any Volatile Organic Compounds emitted during and after the application of the product.
It is calculated based on the standard shade defined in this PDS. Values may vary with shade.
Product Data Sheet – Hempatherm IC 175
Issued by Hempel A/S – April 2025
Document Version: 4/4
Source: https://www.hempel.com
Technical Guidelines and Explanatory Notes
Last accessed: 28 May 2025
Reference link: https://www.hempel.com/service-and-support/technical-guidelines
Note: Always consult the latest version of the Product Data Sheet and associated documents directly from Hempel’s official website to ensure accuracy and compliance with the most current recommendations.