Hempathane Fast Dry 55750 is a 2-component polyurethane paint. Cured with aliphatic isocyanates. Good gloss retention and colour stability. Contains zinc phosphate.
Hempathane Fast Dry 55750 is recommended as a high-build solution for protecting steel structures, in compliance with VOC regulations. The product may be specified as a one-coat direct-to-metal system in corrosive environments classified as C2 and C3. It may also be applied directly on galvanised steel.
Hempathane Fast Dry 55750 can also be used as an undercoated intermediate coat or topcoat within the system.
29°C [84°F]
Legislation | Value |
---|---|
EU | 326 g/L [2.72 lb/US gal] |
US (coatings) | 326 g/L [2.72 lb/US gal] |
US (regulatory) | 326 g/L [2.72 lb/US gal] |
China | 326 g/L [2.72 lb/US gal] |
According to specific legislation, see details in the Explanatory Notes available at Hempel website, hempel.com or at your local Hempel website. VOC values may vary with shade, please consult the Safety Data Sheet, section 9.
Handle with care. Before and during use, observe safety labels on packaging and paint containers and follow all local and national safety regulations. Always consult Hempel’s Safety Data Sheet for this product along with the Product Data Sheet.
For professional use only.
Consult Hempel’s separate Surface Preparation Guidelines for more details.
Base 55759 : Curing Agent 97050 (9.1 : 0.9 by volume)
Stir well before use.
Hempel’s Thinner 08080
Hempel’s Thinner 08080
Product temperature | Pot life |
---|---|
20°C [68°F] | 2 hours |
Tool | Thinning max vol. | Application parameters |
---|---|---|
Airless spray | 5% | Nozzle pressure: 200-250 bar [2900 psi], Nozzle orifice: 0.015-0.021″ |
Brush | 5% | Not Applicable |
Spray data are indicative and subject to adjustment. Pressure is for a material temperature of 20°C [68°F].
Low | High | Recommended | |
---|---|---|---|
Dry film thickness | 50 micron [2.0 mils] | 160 micron [6.4 mils] | 100 micron [4.0 mils] |
Wet film thickness | 77 micron [3.1 mils] | 245 micron [9.8 mils] | 153 micron [6.1 mils] |
Theoretical spreading rate | 13 m²/L [530 sq ft/US gal] | 4.1 m²/L [167 sq ft/US gal] | 6.5 m²/L [265 sq ft/US gal] |
For best performance, avoid excessive film thickness. Product may be specified in another film thickness than indicated depending on purpose and area of use. This will alter spreading rate, drying and curing time and overcoating interval.
Surface temperature | Touch dry min | Hard dry min |
---|---|---|
20°C [68°F] | 60 min | 120 min |
Determined for dry film thickness 100 micron [4.0 mils] at standard conditions, see Hempel’s Explanatory Notes for details.
Quality name | -10°C [14°F] | 0°C [32°F] | 20°C [68°F] |
---|---|---|---|
Atmospheric medium Min / Max | 20 h / Ext* | 12 h / Ext* | 4 h / Ext* |
Ext*: Depending on the actual exposure conditions, the coated surface is overcoatable for an extended period of time. Contact your local Hempel representative for advice.
Hempel’s specification supersedes any guidelines indicated in the overcoating table.
Ambient temperature | Base | Curing Agent |
---|---|---|
25°C [77°F] | 36 months | 24 months |
Shelf life from date of production, when stored in original, unopened containers. Thereafter, the product quality must be re-inspected. Storage at elevated temperatures may reduce shelf life. For advice, please consult Hempel.
Dry film thickness | GWP (Global Warming Potential) |
---|---|
1 µm | 6 g CO₂e/m² |
1 mil | 0.031 lb CO₂e/ft² |
The carbon footprint is for 1 square meter / square foot of surface area with a dry film thickness of 1 micron / mil. The scope includes raw materials, in-bound transport to the Hempel factory, Hempel manufacturing processes, and any Volatile Organic Compounds emitted during and after the application of the product. It is calculated based on the standard shade defined in this PDS. Values may vary with shade.
Product Data Sheet – Hempathane Fast Dry 55750
Issued by Hempel A/S – June 2025
Document Version: 4/4
Source: https://www.hempel.com
Technical Guidelines and Explanatory Notes
Last accessed: 28 May 2025
Reference link: https://www.hempel.com/service-and-support/technical-guidelines
Note: Always consult the latest version of the Product Data Sheet and associated documents directly from Hempel’s official website to ensure accuracy and compliance with the most current recommendations.