Hempatop Repel 800 is a two component advanced water repellent polyurethane coating. The system offers exceptional anti-corrosion protection, robust mechanical properties, and ease of application.
Hempatop Repel 800 is designed to be used as the top coat in a two coat system with Hempel’s Hempadur Avantguard 770, activated zinc epoxy primer, for demanding C5 and CX environments as defined by ISO 12944-2:2018.
Suitable for structural steel, pipe, vessels, minimum two meters above the splash zone.
42°C [108°F]
Legislation | Value |
---|---|
EU | 589 g/L [4.92 lb/US gal] |
US (coatings) | 15 g/L [0.13 lb/US gal] |
US (regulatory) | 36 g/L [0.30 lb/US gal] |
China | 589 g/L [4.92 lb/US gal] |
According to specific legislation, see details in the Explanatory Notes available at Hempel website, hempel.com or at your local Hempel website. Measured according to GB/T 23985-2009.
Handle with care. Before and during use, observe safety labels on packaging and paint containers and follow all local and national safety regulations. Always consult Hempel’s Safety Data Sheet for this product along with the Product Data Sheet.
For professional use only.
Consult Hempel’s separate Surface Preparation Guidelines for more details.
Base 55549 : Curing Agent 98990 (4 : 1 by volume)
Stir well before use.
Hempel’s Thinner 08080, Hempel’s Thinner 08680
Hempel’s Thinner 08450
Product temperature | Pot life |
---|---|
30°C [86°F] | 60 min |
Tool | Application parameters |
---|---|
Airless spray | Nozzle pressure: 150 bar [2200 psi], Nozzle orifice: 0.015-0.017″ |
Brush | Not Applicable |
Air spray | Not Applicable |
If brush or roller application is used, more coats will be necessary to achieve the specified dry film thickness. Spray data are indicative and subject to adjustment. Pressure is for a material temperature of 20°C [68°F].
Low | High | Recommended | |
---|---|---|---|
Dry film thickness | 175 micron [7.0 mils] | 250 micron [10 mils] | 200 micron [8.0 mils] |
Wet film thickness | 293 micron [12 mils] | 419 micron [17 mils] | 335 micron [13 mils] |
Theoretical spreading rate | 3.4 m²/L [139 sq ft/US gal] | 2.4 m²/L [98 sq ft/US gal] | 3 m²/L [122 sq ft/US gal] |
Product may be specified in another film thickness than indicated depending on purpose and area of use. This will alter spreading rate, drying and curing time and overcoating interval. For best performance, avoid excessive film thickness.
Surface temperature | Touch dry hours | Hard dry hours |
---|---|---|
20°C [68°F] | 3½ | 6 |
30°C [86°F] | 2½ | 3 |
Determined for dry film thickness 200 micron [8.0 mils] at standard conditions, see Hempel’s Explanatory Notes for details.
Quality name | 10°C [50°F] | 20°C [68°F] | 30°C [86°F] |
---|---|---|---|
Atmospheric severe Min / Max | 4½ h / Ext* | 2 h / Ext* | 80 min / Ext* |
Ext*: Depending on the actual exposure conditions, the coated surface is overcoatable for an extended period of time. Contact your local Hempel representative for advice.
Hempel’s specification supersedes any guidelines indicated in the overcoating table.
Ambient temperature | Base | Curing Agent |
---|---|---|
25°C [77°F] | 24 months | 24 months |
Shelf life from date of production, when stored in original, unopened containers. Thereafter, the product quality must be re-inspected. Storage at elevated temperatures may reduce shelf life. For advice, please consult Hempel.
Dry film thickness | GWP (Global Warming Potential) |
---|---|
1 µm | 12.9 g CO₂e/m² |
1 mil | 0.067 lb CO₂e/ft² |
The carbon footprint is for 1 square meter / square foot of surface area with a dry film thickness of 1 micron / mil. The scope includes raw materials, in-bound transport to the Hempel factory, Hempel manufacturing processes, and any Volatile Organic Compounds emitted during and after the application of the product. It is calculated based on the standard shade defined in this PDS. Values may vary with shade.
Product Data Sheet – Hempatop Repel 800
Issued by Hempel A/S – May 2025
Document Version: 4/4
Source: https://www.hempel.com
Technical Guidelines and Explanatory Notes
Last accessed: 28 May 2025
Reference link: https://www.hempel.com/service-and-support/technical-guidelines
Note: Always consult the latest version of the Product Data Sheet and associated documents directly from Hempel’s official website to ensure accuracy and compliance with the most current recommendations.